R410A Refrigerant 357KW DC Inverter VRF AC Unit

Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

R410A Refrigerant 357KW DC Inverter VRF AC Unit

  • 1
  • 2
  • 3

Brand Name : EuroKlimat

Model Number : EKRV-EY

Certification : ISO9001, ISO14001, OHSAS18001, CRAA, CQC

Place of Origin : China

MOQ : 1 pcs

Price : Negotiation

Payment Terms : L/C, T/T

Supply Ability : 1500 units per month

Delivery Time : 20 working days after received your payment

Packaging Details : Pallet

Product Name : DC Inverter Multi-connected Central Air Conditioner

Refrigerant : R410A

Cooling Capacity(kW) : 14 kW~357 kW

Ultra-long Connecting Pipe : Max pipe length:1000m

Charging per Customer : Electricity fee can be calculated in real time based on customers' actual usage.

Contact Now

DC Inverter VRF Air Conditioner R410A 14 kW~357 kW

Condensing Unit Cooling Capacity : 14KW-357KW

Indoor Unit Type : Ceilling Concealed Ducted Type, High ESP Ducted Type , Fresh Air Duct Type , Wall Mounted Type ,4 Way Cassette type,1 Way Cassette type,2 Way Cassette,Ceiling/standing type.

Indoor Unit Cooling Capacity :1HP~32HP

Description:

Higher Energy Efficiency

By using a PWM valve to control the time ratio of unloading and loading status, the DC inverter scroll compressor can continuously regulate the capacity within a range of 10%–100%, increasing the precision of capacity regulation and the stability of indoor temperature.

Low Energy Consumption

The unit boasts an outstanding IPLV(C) (refrigerating coefficient of performance). The full series of units features an IPLV(C) that is far higher than China national standard energy efficiency level 1st.

More Advanced Technologies

Quick Start Technologies

EKRV series DC Inverter multi-connected central air conditioners can run in full load within a short period, quickly meeting indoor requirements.

Supercooling Technologies

Enlarges the condenser of the outdoor unit to implement level-1 supercooling, and then uses an efficient supercooler to implement level-2 supercooling, reaching a total supercooling degree of 19.6°C. Enhances the cooling capability of the unit and improves the efficiency of the unit. Reduces the pressure loss when the refrigerant is circulated in the pipe, rationally allocating the ultra-long accessory pipe and refrigerant.

DC inverter motor

Fans of outdoor units can be regulated at 32 levels based on load changes, improving efficiency and reducing noise.

The unit can safely run under partial load for a long time.

Intelligent Defrosting Technologies;

Wide operation range

EKRV series digital multi-connected central air-conditioning units can generate cooling result in ambient temperature of 55°C.

Ultra-long Connecting Pipe

Total pipe length

1000m

Max. equivalent length of a single pipe

220m

Max. actual length of a single pipe

190m

Max. vertical span between outdoor and indoor units

110m

Max. vertical span between indoor units

40m

Easy Installation

The system can provide an external static pressure of 50 Pa, ensuring the heat dissipation result of the outdoor unit under the same installation conditions (optional).

A higher external static pressure ensures that the outdoor unit can be flexibly installed at a rooftop, compartment, balcony, or equipment floor, preventing overload of the unit due to poor ventilation

More Secure

Dual Backup Operation with Guaranteed Security

Automatic Fault Diagnosis

Technologies for Automatic Identification of Pipe Length

Multiple Measures to Effectively Protect Compressors

Door Card Function (Optional)

Intelligent and Balanced Operation Management

Electronic expansion valve

The unit uses an electronic expansion valve with 4000-step capacity regulation to increase the precision of superheat degree control (liquid level control), enhance the operation security, and improve energy saving.

More Intelligent

Centralized Monitoring Software

One set of EKRV centralized monitoring software can control up to 2048 indoor units, meeting customers' requirements for large-scale centralized management.

Separate Control Charging per Customer

The unit can fairly and rationally divide the electricity quantity based on the model, operation mode, operation time, air supply/ return efficiency, and refrigerant flow of the air conditioning unit to protect the rights and interests of all owners. The unit provides customers with functions such as owner management, price and recharge management, energy saving management.

Centralized Control

Models of indoor units are diverse for selection.

Indoor units cover 6 series and 63 capacity types, and total fresh air indoor units are available, fully meeting customer requirements.

More Environment-friendly

Full Compliance with RoHS Directive,

Environment-friendly Refrigerant,

Automatic Refrigerant Recovery Technologies,

Automatic Determination of Refrigerant Charge,

Energy Consumption of 5 W in Standby Mode(a Record Low in the Industry)

Applications

hotels,entertainment centers, hospitals, restaurants, office buildings, cinemas,

factories, school supermarkets and so on.

Specifications

Model EKRV080ER1 EKRV100ER1 EKRV120ER1 EKRV140ER1 EKRV160ER1 EKRV180ER1 EKRV200ER1 EKRV220ER1 EKRV240ER1
Capacity HP 8 10 12 14 16 18 20 22 24
Power supply 380-415V/3N~/50Hz
Rated cooling capacity kW 25.2 28 34 40 45 51 56.5 62 68
Rated heating capacity kW 28 31.5 37.5 45 50.5 57 63 69 75
Rated power of cooling kW 5.85 6.9 8.62 10.37 12.22 13.55 15.03 16.55 17.24
Rated power of heating kW 5.97 7.07 8.96 10.72 12.25 13.62 15.12 16.76 17.92
Rated current of cooling A 11.3 13.4 16.4 20.2 23.3 25.8 28.6 31.4 32.7
Rated current of heating A 11.4 13.7 17.1 20.4 23.3 25.9 28.7 31.8 34
Max working current A 22.5 24.9 25.8 39.1 40.3 45.2 47.1 48.6 51.6
Liquid pipe mm (inch) 9.52 12.7 15.88
Gas pipe mm (inch) 19.05 22.23 25.4 28.6
Pipe connection Liquid pipe Connecting bell-mouthed terminal with threaded joint
Gas pipe Connecting bell-mouthed terminal with threaded joint Welding
Unit weight kg 205 215 235 315 325 345 355 365 370
Sound level dB(A) 56 57 60 60 60 61 61 61 62
Refrigerant R410A
Dimensions (W x D x H) (mm) 920×760×1640 1140×835×1640 1655×835×1640

Model EKRV260ER1 EKRV280ER1 EKRV300ER1 EKRV320ER1 EKRV340ER1 EKRV360ER1 EKRV380ER1 EKRV400ER1 EKRV420ER1
Capacity HP 26 28 30 32 34 36 38 40 42
Power supply 380-415V/3N~/50Hz
Rated cooling capacity kW 74 79 85.2 90 96 102 108 114 119
Rated heating capacity kW 82.5 88 95 100.5 107.5 114 120 127.5 133
Rated power of cooling kW 18.99 20.84 22.4 23.45 25.77 27.1 27.61 29.36 31.21
Rated power kW 19.68 21.21 22.73 23.83 25.87 27.24 28.64 30.4 31.93
of heating
Rated current of cooling A 36 39.5 42.5 44.5 48.9 51.4 52.4 55.7 59.2
Rated current of heating A 37.3 40.2 43.1 45.2 49.1 51.7 54.3 57.7 60.6
Max working A 64.9 66.1 71.1 73.5 75.5 78.5 85.5 90 92.5
current
Liquid pipe mm 19.05
Gas pipe mm 31.8 38.1
Pipe connection mode Liquid pipe Connecting bell-mouthed terminal with threaded joint
Gas pipe Welding
Unit weight kg 480 485 510 515 545 550 575 580 585
Sound level dB(A) 62 62 63 63 63 63 63 63 64
Refrigerant R410A
Dimensions (W x D x H)   1780×835×1640 2615×835×1640
(mm)


Product Tags:

DC Inverter VRF AC Unit

      

357KW VRF AC Unit

      

R410A Refrigerant VRF Air Conditioner

      
Best R410A Refrigerant 357KW DC Inverter VRF AC Unit wholesale

R410A Refrigerant 357KW DC Inverter VRF AC Unit Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0